Changes in EasyView


Rev 5.7.2.3 (10-11-05)
- Faster presentation of time-stamped data

Rev 5.7.2.2 (10-10-21)
- Corrections in handling of time-stamped data

Rev 5.7.2.1 (10-10-06)
- Import of big files with time-stamped data works

Rev 5.7.1.2 (10-04-19)
- Copy datalist works

Rev 5.7.1.1 (10-04-15)
+ Data reduction in datalist view based on time interval
- Average of time-stampled data was wrong

Rev 5.7.1.0 (10-04-07)
+ Support for CME Value Report

Rev 5.7.0.2 (10-03-18)
- Corrections in handling of formulas

Rev 5.7.0.1 (09-10-18)
+ Support for MSR files

Rev 5.6.4.2 (09-06-01)
- Writing comments works
- Copied datalist is right

Rev 5.6.4.1 (09-01-13)
- Multimeter works with "Gemini Tinytag on Auto"

Rev 5.6.4.0 (08-12-08)
+ Simpler handling of Tinytags with "Gemini Tinytag på Auto"

Rev 5.6.3.0 (08-02-26)
+ iButton driver
+ Support for new Comet-sensors
- COM-portar with number higher than 9
- Corrections in GPRS-import
- Printing works better.
- Alarm plugin handles COM-ports better
- Publisher can make .gif pictures

Rev 5.6.1.0 (07-03-01)
+ Works with Windows 2003 and Vista
+ Support for Comet
+ GPRS import
+ Installation by MSI
+ Language selection
+ Com-ports up to 32 scanned
- Tinylogger RH can be limited at 100%
- PC-Loggers without range selection with thermo-inputs handles type of sensor right.
- DDE client did not work with Excel-compatible DDE-links.
- When Import can not identify the format of dates, then European standard is default.
- EasyCall could not create new files only append to existing.

Rev 5.5.1.5 (03-09-10)
+ Support for the new PC-Loggers 3100i and 3150i added.
+ New realtime client running OPC/DDE in separate thread. More tolerant connection.
- File association problem of .ezv files corrected.
- Background image in the Process diagram was not published in Publisher.
- The Process diagram can now handle wmf images.
- ACR: The channel configuration replaced. Now using Wizard mode.
- The y-axis did not change unit when transforming a channel to a differen unit.
- The Duration diagram did not update when time diagram tab was changed.
- Import of two channel tiny recordings reported the wrong unit.
- The file path to load/save formulas in the formula pane was not saved.
- Calculation error of the funktion ATAN in the formula plugin corrected.
- Å,ä and ö can now be used in the recording title for tiny recordings.
- EasyCalls location dialog was not working correctly.
- The label of the alarm plugin can now be changd.
- Tabs in the time diagram and info table does not allow the same name.
- Using a document as template did not transfer transform properties to the new document.

Rev 5.5.1.3 (03-02-28)
+ Feature to import Tinylogger files added (*.ttd)
+ Importing as time stamped data now ignores repeated values.
- The channel transform saved in documents prior to 5.5 was sometimes incorrect.
- New OPC browser which avoids incorrectly implemented OPCServer functionallity.
- The Duration plugin rendered the diagram incorrect.
- Auto restart using AAC-2F only created temp files.
- On-line recording using PC-Logger could crasch if you were using ave, min and max.
!  OPC Server mirroring to a database file removed due to incompatible API technologies.

Rev 5.5.1.1 (03-01-02)
+ New information column added in EasyCall (Last successful attempt).
- EasyCall was malfunctioning.
- Channel linking where the interval differed did not work correctly.
- Measurement data could disappeared when adding an operator channel.

Rev: 5.5.0.14 (02-11-05)
- If the toolbar file Toolbar3.cfg was corrupted EasyView would crasch at program start.
- The Project Manager did not get settings from the logger when offloading.

Rev: 5.5.0.13 (02-10-31)
+ Swedish version of the new Tiny logger driver.
+ Tinytags can now be programmed with a password.
- Comment tags could appear with incorrect information. Possible even crasch.
- Printer problem when incorrect print area selecte is fixed.
- The formulas was not allways marked red when syntactical errors occurred.
- Logger history could be wrong the first time a logger connected.
- "Stand-alone" & character now works in tab names.
- The import missed the first line if decimals were missing but later appeared.
- AM/PM was not accepted in the diagram properties.
- PC-Logger start error, allways selecting T/C type K corrected. Arised in 5.5.0.0 

Rev: 5.5.0.12 (02-10-09)
+ OPC Real-time client: An option to "copy" the namespace of an OPC server to a local .mdb database has been added.
- OPC Real-time client: The option to select browseing of 1.0 and/or 2.0 was missing in the English verison.
- OPC Real-time client: Nodes with tags on the same level did not work.

Rev: 5.5.0.10 (02-09-25)
+ OPC Real-time client: Major improvments when browsing and connecting to OPC Servers.
+ OPC Real-time client: Signals that were extended due to slow and random data change could hide "real" values.  
+ OPC Real-time client: You can now select if you want to browse both 1.0 and 2.0 or one of them.
+ OPC Real-time client: Local timestams can be set to replace them from the OPC Server.
+ The driver Gemini Tinyloggers now works with inductive loggers.
- "Floating point error" could sometimes appear when generating a graph popup.

Rev: 5.5.0.4 Beta Final Release Candidate (02-06-20)
+ Support för PC-Logger 3100, 3150 (RTC V3022).
+ Ändrad katalogstruktur.
- "Viktningen" för hur en datarad tolkas i importen justerad. Klarar mer skräptext i dataraderna.
- Publicerades Processdiagrammet behövde den vara aktiv för att ändras.
- "Explorer-dialogen" vid val av sökväg sorterade ibland felaktigt.
- Interpolerar aldrig vid trappstegsgrafer.

Rev: 5.5.0.0 Beta Release 1 (2002-04-16)
+ NY Gemini drivrutin.
+ EasyView kan nu köras som "begränsad användare" i NT/2000/XP.
+ Sökvägsval i "Öppna" och "Projekthanteraren" har Explorer-utseende.
+ Positionslist tillagd.
+ Infotabellen kan vändas i X/Y. Kolumner blir rader etc.
+ Växla vy-placering. Infotabellen till vänster och plugins/tidsdiagram över och under.
+ Minutflagga tillagd vid "Autoflaggor".
+ Aktivering av plug-ins sker dynamiskt mot aktivt dokument. (Gäller ej då en server är aktiv)
+ OPC/DDE: Ny Realtidsklient (OPC/DDE) med smidigare hantering/redigering av mätpunkter. 
+ OPC: Automatiskt stöd för multipla grupper med intervall i anslutna OPC servrar.
+ OPC: OPC Dödband stödjs / kanal (Nödvändiga grupper skapas automatiskt).
+ OPC: EV-kanalers intervall är samma som OPC serverns uppdateringsfrekvens för grupp.
+ Möjlighet att ställa in utseende för ASCII-export (kopiera data).
+ Nytt "visa index istället för tid" val i datatabellen.
+ Vid nytt tabellavsnitt anpassas kanaler så det blir lika många i varje. 
+ 'Tårta', 'Stapel' och 'Text' support i Processdiagram. 
+ Öppna: Sammanfoga till befintligt dokument, inte bara i nytt. (Ej till öppet dokument!)
+ Projekt: 'Töm till'/'Starta online i' befintligt dokument. (Ej till öppet dokument!)
+ Ny Process-rendering ger fungerande och snygg presentation även för onlinemätningar.
+ Ny XY-rendering ger fungerande och snygg presentation även för onlinemätningar.
+ XY snabbare.
+ Ny Histogram-rendering ger fungerande och snygg presentation även för onlinemätningar.
+ Ny Varaktighets-rendering ger fungerande och snygg presentation även för onlinemätningar.
+ Alla diagramplugins stödjer nu gummibandsaxlar och gummidiagram.
+ Flytande kommentarrutor i Tids-diagrammet (Tips - kopiera och klistra in från infotabellen!).
+ Flytande kommentarrutor i XY-diagrammet (Tips - kopiera och klistra in från infotabellen!).
+ Flytande kommentarrutor i Histogrammet (Tips - kopiera och klistra in från infotabellen!).
+ Flytande kommentarrutor i Varaktighets-diagrammet (Tips - kopiera och klistra in från infotabellen!). 
+ Auto-färdigställ funktion i formeleditorn via Ctrl.
+ Nytt länkmakro i tidsdiagrammets kommentartaggar: <keyval:MAX> etc.
+ Processdiagrammet kan nu publiceras via Publisher PlugIn.
+ JPEG stöds för publicering.
+ Excel (.xls) dokument kan öppnas direkt (Kräver Excel 97 eller senare på datorn)
+ Projekthanteraren: 'Splitbar' mellan projektträd och infotext tillagd.
+ TABLE(r; n) -> Flerpunktstransform för formelpaketet. ('TABLEn.TXT' i programkatalogen)
+ Sidhuvud kan innehålla bild. ('logo.bmp' i programkatalogen)
+ kx+m kolumn som visar N/A om tranform ej är aktiverad. Heter 'Transform' på svenska.
+ X/Y-diagram kan visa punkter istället för linjer.
+ Tinyloggrar med helt minutintervall synkroniseras till hel minut vid tömmning.
+ Importen tillåter att importera som sekvensiell data. Mindre filstorlek. (Ignorerar tidskolumn)
- Projekthanteraren listar nu bara en katalognivå i taget.
- Befintliga dokument visade alltid "Spara doku.." då det öppnades.
- Tinytag: Larmnivå FML tar nu hänsyn till om '.' eller ',' skall användas.
- Frekvent använding av gula "popup"-fönster kunde få programmet att krascha.
- Formelkanaler visas inte längre i DiagramEgenskaper\Transform
- OPC-browser kommer ihåg senast laddade serverlistan.
- EasyView kunde skapa 0kB .gif-bilder på grund av minnesläcka.

Rev: 5.1.1.11 (02-09-25)
- Some new and repaired Tinytags returns ver 2.3 which EasyView now supports.

Rev: 5.1.1.10 (02-08-07)
- When starting buffered online with a long sampling interval EasyView could freeze.

Rev: 5.1.1.9 (02-05-31)
- When start failed using a project EasyView sometimes crasched.
- Alarm plugin: Malfunctioned when using OPC signals.
- Alarm plugin: Alarm relay box connected to COM-port even when not recording.

Rev: 5.1.1.7 (02-02-28)
- Gif files were not created correctly.

Rev: 5.1.1.6 (02-02-25)
- Projects using PC-Logger 2100 used incorrect presentation parameters on channel eight and higher.
- The limitation that a maximum of eight windows could be shown has been removed.
- Transforms were not saved in projects with OPC/DDE.

Rev: 5.1.1.5 (02-01-16)
- Faxis, Printer ports and other irrelevant lines are no longer shown under File/Connections in Windows 2000 & XP.
- Histogram reduced in amplitude during on-line session.
- Logger specific transform for online Tiny recordings did not work properly.
- Import of ambiguous time/date was interpreted incorrectly if placed in the same column.

Rev: 5.1.1.4 (01-12-13)
- If the bottom info table row was not completely visible it was not included in printouts. 
- The thousand separator could not be interpreted in 'Diagram properties'.
- The 'split bar' in the formula editor was not redrawn correctly.
- Double click on the 'Title' opened an incorrect dialog.
- 'Save as project' when starting a new OPC/DDE recording failed.
- Clicking a folder in the 'Project manager' failed. Error introduced by 5113.
- The import could not recognize % and ° as prefix on units.
- Formulas were sometimes not saved when starting new recordings.

Rev: 5.1.1.3 (01-11-20) 
- Buffered on-line: Data reduction and ave/min/max recordings were not supported.
- Newly opened document showed incorrect ave/min/max in info table.
- 'Open view in new document' with timestamped data did only copy one sample (import)
- X/Y diagram now much faster with time stamped values (import).
- Sampling rate and deadband in an OPC project were not saved.
- Print preview with X/Y diagram froze the application.
- Click on the 'Auto' button in a PC-Logger project caused a crasch.

Rev: 5.1.1.2 (01-10-30)
- Import : Unit recognition improved.
- Import : Long time span corrected.

Rev: 5.1.1.1 (01-10-01)

- The 'Remove' button in DDE/OPC properties was never activated.
- 'Update project' under Edit did not save the latest changes.
- The import could crash if data were mounted in existing recording. 
- Time stamped data was not copied when opening files overlaid.
- The Histogram froze EasyView when an axis values was 'mirrored' 
- Space before a text value was not removed when imported and was therefore interpreted as faulty.

Rev: 5.1.1.0 (01-09-20)
+ The import format recognition has been rebuilt and improved. New easier user interface added. The import filter has been removed.
- The XY diagram was sometimes not correctly drawn.

Rev: 5.1.0.14 (01-08-17)
- EasyCall
could crash if using COM port instead of modem.

Rev: 5.1.0.13 (01-08-06)
- On-line with the 24:rd channel on a AAC-2 resulted in an incorrect value using projects.
- Buffered on-line could fail after about an hour.

Rev: 5.1.0.1
2 (01-06-28)
- DDE recordings could sometimes get an incorrect starttime. Resulted in an end time year 2034.

Rev: 5.1.0.11 (01-06-27)
+ Support for INTAB Alarmbox 1.00 added.
+ The interval for buffered on-line can now be selected freely. 
- Improved security and recovery when loosing the connection using buffered on-line. 
- The Publisher always added.txt on text files. Any extension is now allowed.
- The thousand separator can be removed selecting “0 numbers in group” in the control panel.
- The installation now removes previous .ezx dll’s to minimize version conflicts. 
- The line width when printing was to thin for the Duration diagram and the Histogram. 
- Tinylogger driver sometimes selected 4800 baud.
- The Cursors in the time diagram could disappear stopping on-line recording.

Rev: 5.1.0.10 (01-05-31)
-
The Project manager incorrectly required Internet Explorer 4.71 or later. IE4 is sufficient.
-
The Data table truncated the time column if thousands of a second were used.

Rev: 5.1.0.9 (01-05-29)
+
Right button click on a project allows you to create shortcuts for start/stop/offload directly on your desktop. New icons.
   (Requires IE 4.71 >>)
+
Update a project presentation from a recording. "Edit/Update project" added in the menu.
+
Maximum number of opened windows increased to eight.

-
The Project Wizard did not warn when creating a new project with the same name as a present one.
-
The DDE Server went blank if you didn't close the first document before starting a new one via projects.
-
The Project Manager was not activated in the Demo version.
- The Formula editor did not handle X^(1/3) correctly. (3:rd square root of X)
-
CONST declarations in the Formula editor did not handle more than eight decimals.

Rev: 5.1.0.8 (01-05-16)
+
Alarm plugin available.
-
Starting an off-line recording of a PCLogger via the Project manager resulted in an 'OK' message. Removed.

-
The
"Buffered" online checkbox in then PCLogger Wizard was not deactivated when using loggers without memory.
-
Creating a new project using an old .ezv file, no warning was displayed.
- Offloading an AAC-2F via a project generated a program error.

Rev: 5.1.0.7 (01-04-05)
+ PCLOGGER:
Off-line buffering of on-line recordings implemented.
+
New off-load alternatives in the Project manager.
- PCLOGGER:
Selecting only Min and Max resulted in Min, Max and Ave
- The link alternatives' dialog was in Swedish only.
-
Opening presentation in a project involving a real-time client could crash.
-
Deactivation of channels in the Project manager was impossible.
- PC-logger via modem i
n the
project manager was not in "quiet mode".

Rev: 5.1.0.6 (01-03-12)
+
Criteria for 'join equal channels' in Open, are programmable.
+ EasyView
inhibits power save settings.
+ Import
filter now handles two time columns: date and time.
+ Import
filter now handles "multiple whites".
+
Interpretation of time of imported data improved.
+ Standard
transform for Tinyloggers associates with serial number via Connections/Settings.
-
Settings of channels with quoted (") channel names "disappeared".
- Some channels lost.
- Skew factor not saved
-
No of decimals was not saved.
-
Y-axes order did not load properly.
- Version
check of Tinyloggers accepts ver <= 2.2.
- EasyCall
did not work together with modifications of IRIS.
-
Crash if no recorder driver was selected.
-
Time format didn't follow control panel settings of AM/PM.
-
Project Presentation template did not accept formulas.
-
Detection of Pro or Light turned out wrong.  Project manager not shown.
- Tiny
-logger supported by the Project manager.
- Proje
ct manager had on-line as default for new PC-logger projects.
- Proje
ct manager buttons were not up-dated at Stop.
-
Endless memory on-line, was not supported by the Project manager.
-
The Project manager included in the light by mistake.
- O
ff-loading tinies via a project crashed.
- N
ewt project shows only selected media instead of all.
- S
ave after off-load of Tiny crashed.
-
Preview of Duration crashed.
- Sort
ing of signals in the presentational template made sensible.
-
Path error to templates in Win2000 corrected.

Rev: 5.1.0.0 (01-02-01)
+ OPC client
+ OPC server
+ DDE server
+
Duration diagram.
+ Do
cument templates handled by the Project manager.
+ Proje
ct manager.
+ Start projects by double-clicking .ezt file. Add /start, /stop or /offload arguments to shortcut.
+ Logger
history in separate dialog.
+
Serial number section of the licence number is shown in properties.
+ .EZV
properties shown in the explorer: recorder, user etc.
+
Header/Footers saved in document
+ Tiny:
opens and closes the serial port only once. Avoids I/O contention.
+ Tiny:
improved status messages. X-fer disabled if delayed start has been programmed.
+
"Open" may be printed.
+
Default Comment tag text now programmable.
+
AAC-2 RTC synced to whole second.
+ Real
-time on/off affects only active tab.
- Real
-time off, also stops up-dating of info-table and plug-ins.
-
Open sorts correctly
- Form
ula editor ignored the line directly below faulty line
-
No T/C choice if non T/C units are connected.
- Modem
will hang up prior to OK after transfer is completed.
-
Nomenclature changes in AAC-2 wizard Data reduction.
- Process
renamed Process diagram.
- Drag'n-drop
placed data temporally wrong.
- PC
-Logger\Parameters allowed offline programming of units without memory.
- PC
-Logger F does not support DMM while recording. DMM will show N/A without interfering with SEND:.
-
Imported ASCII always positioned data at origin "0" even if time info was present
-
Partly (aborted) transferred EasyCall file deleted. Correct "x-fer from" time.

Rev: 5.0.0.8 (00-10-25)
- XY diagram caused program crash with some files. Didn't have to be the "active" plugin.
- LambdaTune sometimes created incorrect formulas.
- Extended "timeout" when connecting to DDE (4s -> 10s).

Rev: 5.0.0.7 (00-09-11)
- Linked documents with overlapping channels generated a program error.
- Spectrum.dll was missing in Servicepack 5006.

Rev: 5.0.0.6 (00-08-30)
- EasyCall did not start correctly.
- LambdaTune did not plot the generated signal correctly when opening the document.

Rev: 5.0.0.5 (00-08-15)
+ Optimizing the graph plot. Much faster on large recordings.
- Print preview could crash printing data table.
– Data table now updates correctly online.

Rev: 5.0.0.4 (00-06-26)
- Save as image didn't return all resources to the system.
- The DDE client sometimes failed to detect a signal.

Rev: 5.0.0.1 (00-05-17)
- Text import could not handle large differences in the values (eg. 10E+2 to 10E+30).
- Doubleclicking an .EZV file didn't always open the file.
- EasyView froze if a formula line began with a bracket.
- If two "KEYVAL" was declared with the same name a krasch occurred.
- The diagram graphs were not redrawn when selecting "Update now" in the formula editor.
- "Save as" didn't save last used folder.
- The background image in the process diagram didn't disappear when the link was removed.
- Converting PS-Soft files to EasyView faild.

Rev: 4.1.0.8 (00-02-23)
- EasyCall does not create "empty" data packages when offload fails. It now handles shorter sampling intervals than storing interval (not recommended though). Correcly handled when recording has stopped.

Rev: 4.1.0.7 (00-02-11)
+ Modem option to ignore connection message and always use error correction added.
+ Progressbar added when exporting data.
- 'Long date format' showing day of week in the 'Control Panel' was incorrectly handled.
- Negative values using +E (power of ten) were incorrectly handled when importing text data.
- LambdaTune: Parameter selection was not saved.
- LambdaTune: The offset slider could not be pulled into negative values.

Rev: 4.1.0.6 (00-01-04)
- "Fast sweep" of graphs was not updated when running on-line.
- All modems in Windows 95 were presented as <Unknown>. Corrected! The problem "arrived" with 4.1.0.0.
- The Open diagram list lost the last character on each line.
- EasyView could not interpret the time in Diagram Properties if using two number your (eg. mm-dd-yy).
+ New driver for Tinyloggers. OTLMAPI.DLL v4.18.

Rev: 4.1.0.5 (99-12-09)
+ PCLogger : Batch calibration of multiple channels supported.
- Mean value was incorrect when measuring on-line.
- When combining online recording, links are always used.
- Rare crashes when measuring on-line corrected.
- File listing in "Open" dialog just presented the first recording in some operative systems.

Rev: 4.1.0.4 (99-11-25)
+ Improved on-line capabilities and handling of large amounts of data.
+ Info table values now valid when animating or measuring on-line.
+ Diagram and time axis synchronised when measuring on-line.
+ Visual improvements in the info table (no blinks etc.)
+ EasyView shows program version in the EasyView title field (Light, Pro).
+ Fat lines now also handles dotted line.
- Fat lines slowed down the drawing process.
- Crash after message that the AAC needs reboot fixed.
- Corrupt "transform information" now handled. Only visible to "old" AAC-2:s.
- You can now import large files from diskette.

Rev: 4.1.0.3 (99-11-09)

+ New setting for Tinytags (File/Recorder con...), on/off of auto detect.
+ High priority on all tiny communication. Launch should work on "critical" computer COM ports.
+ Improved visual response for the Tiny progress bar.
- Program crash when printing corrected.
- Status in the Recorder Manager was not shown when detecting "new" loggers.
- If a malfunctioning logger was connected a serial number of -1 was presented in the RM.
- [n] operator in the formula editor did not work in 4.1.0.2.
- Text imported files could not contain "Operator channels".
- The Recorder Manager did not consider the situation when the battery was changed.
- Sorting files and latching between file name and title in the Open dialog did not work correctly.

Rev: 4.1.0.2 (99-10-26)
+ New Tinylogger driver. OTLMAPI.DLL version 4.16.
+ "Current settings" in the Recorder Manager is not chaned when using "Change parameters".
+ Question if to stop an on going recording when offloading a Tinylogger in the Recorder Manager.
+ New text import format added. Short date in the text file but long in the control panel.
- Memory leak corrected in the Recorder Manager.
- Status column in the Recorder Manager could sometimes be incorrect.
- "Personal notes" in the Recorder Manager was not saved.
- Alarm settings in the PC-logger Wizard were incorrect when using a template.

Rev: 4.1.0.1 (99-09-15)
- The diagram plot used to much "system time" slowing down other processes.
- Formulas using other formulas were not updated correctly when changed.

Rev: 4.1.0.0 (99-09-10)
+ Graph animation. Interval programmed in 'Options'.
+ Comment tags are linked to Label, Value and Unit.

+ Proper full screen.
+ Improved comment tags. (In one or all tags, handle to graph, multiple lines)
+ Considerable improvements of graph presentation. You gotta see it to beleive it!
+ RecMan extended. Handles start, stop and upload of all loggers. Wizard without logger connected. (Deactivated by default)
+ Temp files can be opened in the Browser.
+ Ny kontroll i Browsern. Iconer mm.
+ File/Open is now the "Browser". File/Register is gone.
+ [n] operator in the formula editor.
+ Save open view as new file.
+ Automatisc adjustment of column width in the Info table by right clicking.
+ Header and Footer on printouts added.
+ "Difficult" units (like °C .. ) preprogrammed in the transform.
+ DMM shows channel names. Enlarge now possible.
+ Support for Tinytag Ultra two-channel loggersr. (also in 4.0.0.7)
+ Operator channels - create "manual" channels.
+ Calculation of key values. New calculated columns in the Info table.
+ New info table columns: 'Square sum' and 'N'. Enables calculation of variance and std. deviation.
+ Column width saved with document.
+ New pop-up in Info table - sort channels.
+ The order of channels in the Info table may be altered.
+ Improved Tiny DLL does not freeze at connect to defect logger.

- Import of text files fimproved. Sometimes unable to identify time column. Empty lines allowed between data and header.
- PC-Logger start without template did not give manual start as default.
- Bugg as a result of multiple data packs in the same file cured. "Channels disappeared".
- Import of 2 channel ttd:s didn't work. Remedied!
- Alarm in 2 channel tinies didn't work. Fixed!


Rev: 4.0.0.9 (99-08-30)

- The Tinylogger module sometimes lost contact while connected in the Start/Stop/Offload dialog.

Rev: 4.0.0.8 (99-06-15)
- The column width was not saved. Fixed!
- The reduction factor in the PC-Logger Wizard did not activate the
   Ave, Min and Max check boxes when set to a value greater than one.
- Start of PC-Logger did not default set manual start on logger display.
- If a presentation template was created when the active document was not saved, old parameters were used.
+ EasyView halted if an faulty Tinylogger was connected. (New dll).

Rev: 4.0.0.7 (99-05-11)
- If more than 13:n characters were used in the PC-logger channel names a program error occured.
- When using 'Save after offload' with Tinytags the file was never created.
- Import of two channel logger .ttd files did not work correctly.
- Two channel logger alarms did not work.

Rev: 4.0.0.6 (99-04-22)
+ Support for new Tinytag Ultra two channel logger added.
- Problem occurring when several data packages were added in same file. Channels 'disappering'. Fixed!
- When importing a text file EasyView accepted a row with only 'spaces' as start row. Fixed!
- If a new comment tag was added and not unmarked when switching to other page a program error occurred. Fixed!
- The dialogue for changing data reduction in the data table generated a program error. Fixed!

Rev: 4.0.0.5 (99-02-04)
- Autoscale of an y-axis sometimes crasched the application. Fixed!
- The data import could sometimes place values in the wrong column when "space" was used as separator. Fixed!

Rev: 4.0.0.4 (99-01-21)
- The installation did not create shortcut to EasyCall. Fixed!
- LambdaTune Plug-in printouts fixed.
- Better routines for Tinytags communication.
- New standby dialog when large text data files are imported.
- Small bugg fix in Import filter. Ignore character and space.
- Printout from History was incorrect. Fixed!
- The recording title was not saved if changed. Fixed.
- The font dialog appeared when clicking "Browse" button. Fixed.

Rev: 4.0.0.0 (98-10-26)
+ Grid can be switched off in time diagram, histogram and XY-diagram individually.
+ Data table editing.
+ New printout features in "History".
+ Histogram available.
+ Process diagram available.
+ Templates now save presentation info as color, format etc.
+ Templates saves formula package.
+ Lock of time unit on time axis supported.
+ Data import available!
+ Combine files without links (Embed).
+ New command in the File menu: Properties.
+ File/Export to file.
+ New toolbar for quick change between communication lines added.
+ New tree control when choosing formula package functions, variables etc.
+ Formula news: If you exclude (unit) in the formula declaration the formula is calculated but not plotted!
+ Formula news: Vector functions can via a FML declaration be used as argument in other Vector functions.
+ LambdaTune available.
+ EasyCall available.
+ Wrap-around-memory on-line (HD). (Only PCLogger).
- The yellow popup used "Original label" instead of "Label". Fixed!
- New OTLMAPI.DLL with Tinylogger bugg fix.
- When changing the interval (Tinyloggers) the character could change. Fixed!

Rev: 3.3.0.11 (99-02-15)
- The same OTLMAPI.DLL as in EV4.0.0.5. Better Tinytag communication.

Rev: 3.3.0.10 (98-11-17)
- If a template was created using a "new" logger with software range switching and applied
  on to an "old" logger with fixed ranges a program error occurred. Fixed!

Rev: 3.3.0.9 (98-10-12)

- If the Y axis was turned up side down (lower values over higher) the application would crasch at rescaling attempts. Fixed!
- If a reduced data table was copied the values would differ from the table when pasting them. Fixed!

Rev: 3.3.0.8 (98-09-15)
- AAC units without sync sometimes lost channels when starting online recording. Fixed!
- Histgrm.ezx was delivered with the installation by mistake. Fixed! (Not corrected by Servicepack)
+ MFC42.DLL is placed in local program directory due to WIN NT conflict. (Not corrected by Servicepack)

Rev: 3.3.0.7 (98-08-17)
- Linked files (overlayed) that contained formulas could not be opened. Fixed!
- If a timout occured while calling a logger recipient the port were not closed correctly. Fixed!

Rev: 3.3.0.6 (98-08-12)
- Linked files (overlayed) that contained formulas could not be opened.

Rev: 3.3.0.5 (98-07-03)
+ EasyView adapted to handle Tinytag 12-bit.
- Minor calculation error in data table when using vast reduction fixed.

Rev: 3.3.0.4 (98-06-22)
- The average cell in the info table had a rounding error. Fixed!
- The info table was not updated when applying a layout template. Fixed!
- When starting an AAC-2 loggers using counters and a recording template, the values could be incorrect. Fixed.
- Envelop errors drawing the graph (graph partially not redrawn) fixed!
- Empty Tinyloggers can not be offloaded.

Rev: 3.3.0.3 (98-06-08)
- Starting a new on-line recording using a template, the y-axis values were not transferred. Fixed!

Rev: 3.3.0.2b (98-05-06)
+ Zooming feature added. Zoom every hour, week, month and so on, back and forth with the help of time flags.
- The Printer setup affected the Windows standard setting. Fixed!
- Changing paper size while setting up printer was ignored. Fixed!
- The digital markers were placed in the left edge when starting a on-line recording with samp. >1sek.
- AAC-2F V2.11 did not function i multimeter mode. They miss 'sync' and are now handled differentely.
* All recordings made by Tinytags now use the recording title as label.

Rev: 3.3.0.1 (98-04-09)
- Tinyloggers using Min & Max while recording could not be offloaded. Fixed!
- A linked recording was not saved correctly. Fixed!

Rev 3.3.0.0 (98-04-03 Upgrade)
+ A snap function that only allows the digital markers to "stick" at actual samples introduced.
+ A magnetic function added to the time axis. The even values tends to stick at the origin and extent position.
+ Zooming with the help of time flags.
+ The data table follows the format of the time axis.
+ Extended formatting capabilities for time axis and data table.
+ New item added to the File menu. Print setup.
+ Option to change printing contents within the print preview window.
+ EasyTerm 3.0.
- Klicking the on-line recording button while on-line and select No did abort the session anyway. Fixed!
- The first average value in a data reduced data table were incorrect. Fixed!

Rev 3.2.0.8 (98-04-02)
-TinyTag Rh+ using the new sensor works correctly.
-Versions of EasyView lower than 3.2.0.4 were not correctly updated
  with the Service Pack 3.2.0.7(b)  (only Tinytags effected) Fixed.

Rev 3.2.0.7b (98-03-18)
-Template linear transformation correctly transferred.

Rev: 3.2.0.7 (98-02-12)
- Problems setting alarm levels when starting new recording solved.
- Only NT 4: Copying the diagram area in into a META format corrected.

Rev: 3.2.0.6 (98-01-30 Only Russian)
* Exactly same version as 3.2.0.5 but in Russian.

Rev: 3.2.0.5 (98-01-28 Only TinyPro version)
- Template function using alarms implemented!
- EV now also recognises *.TTD; not only *.ttd.
- "Tinies" showed powerup warning upon connect. This message will now be presented upon 'Offload' instead.
- Multi-selection in the Diagram/Presentation's tab now works in NT 4.
- Printing does not crash if all plug-ins are disabled.
- Using GSM M1, EV sometimes declared that the logger needs to be booted. Fixed!
- The "Auto" calibration button in the Recording Wizard now uses the correct measuring range weight.

Rev: 3.2.0.4 (97-12-09)
+ Primitive form of printing layout tool added.
- If multiple panes were used in the info table, the visible channels were not necessarily shown on printout.
- The "Auto" button in the Recording Wizard didn’t use the correct measuring range. This resulted in strange values when trying to calibrate the channel.
- When Off-loading a recording where the counter channels were transformed, the untransformed unit was used.
- Tinytag %Rh returned 0,00 values. Fixed in new OTLMAPI.DLL
- EasyView lost connection in some systems using Windows NT4. Fixed!

Rev: 3.2.0.3 (97-11-17)
- The EasyView installation program updates EasyView.ini if found instead of overwriting it. There for keeping font information etc. from earlier installation.
- From EV 3.2.0.1: TinyTalk II didn’t work properly. Tried to send alarm levels that didn’t exist. Fixed!
- In the Record Wizard clicking the Abort button after clicking the "Auto" button hanged the system. Fixed!
- When clicking the "Auto" button in the Record Wizard the wrong gain were used resulting in incorrect calibrated values.
- EasyView halted in Windows NT. Fixed!

Rev: 3.2.0.2 (Will never be released due to final stage problem )
* EasyView sometimes freezes in Windows NT 3.51

Rev: 3.2.0.1 (97-11-12 Test release)
+ Printing option in the History dialog added.
+ Thermocouple type selection added in Multimeter (DMM).
- DMM: The channels values changed places in 3200. Fixed!
- AAC-2F had a problem when logging on-line. Fixed!

Rev 3.2.0.0 (97-10-27 temporary release)
+ TinyLogger support added.
+ A new feature named History has been added. Keeps track of logger status.
+ Alt-I option added (Info). Placed under the Help menu.
+ Placing the mouse on top of a graph activates a Yellow-notice-popup presenting current channel and value.
+ Formulas repositioned to the plug-in field.
+ Button in View/Toolbar named "Standard" added used to restore the toolbar to its original look.
- The last page in Record Wizard was missing for the AAC-2F. Fixed!
- The block size (RS-232) was too small for modems to activate data compression. Now four times as fast.
- DMM used SEND:xxx instead of REPEAT. SEND:xxx could lead to changing the logger setup.
- Loggers with fixed temp input channels. EasyView sent wrong thermocouple type to logger.
- Fullscreen mode didn’t work properly. Fixed!
- Open combined recordings now ignores that serial numbers differ. You can still combine them into one channel.
- The Data tables' scrollbar sometimes returned to the "zero" position in the top when releasing the mouse button.
-" Save as". Known problem that crashed EasyView and the entire computer when saving a Diagram Document. Fixed!


Rev: 3.1.0.2 (97-06-12)
+ Number of decimal edit box for info- and data table added in the Presentation tab. (Diagram Properties)
+ The installation program now deletes the old files with extension .cll, .pll, .rll, .vpl
* Known problem: The browser may crash when displaying old .AAC-2 files where some of them are incomplete.
* Known problem: "Save as" may crash under particular circumstances.
- Adding a modem sometimes disabled the other installed COM-ports. Fixed!

Rev: 3.1.0.1
+ Improved Enhanced Meta File when copying the diagram area.
+ All "DLLs" are now called .ezx.
- The Data table had a cache problem resulting in incorrect placed values. Fixed!
- Converting files from DOS is now saved in local area time. No time zone information!!! Handles the "travel-problem".
- Some language mishaps corrected.

Rev: 3.1.0.0
+ New DLL’s used. MFC42.DLL, MSVCRT.DLL and MSVCITR.DLL
+ The plug-in Data table added.
+ Copy support added for the info- and data table.
+ Copy support of the Diagram area to a Meta File Format (.WMF) added.
+ Floating toolbars added.
+ Diagram and info table templates' tools added to a toolbar. (hidden at first)
+ Corrected help file. (Index words)

Rev: 3.0.0.2
- The info table didn’t update when the diagram was rescaled.

Rev: 3.0.0.1
+ Several diagram areas can be kept under different tabs.
+ Plug-ins XY-Diagram and Notes added.
+ AAC-2F sampling interval at on-line at 50ms!
+ On-line logging via modem allowed.
+ Introducing temporary files. Therefore following features are added: Save as, Sent to, several users having the same file opened etc.